E-PES-S Series General Grade PES Pleated Filter Cartridges
E-PES-S Series polyethersulfone (PES) pleated filter cartridges provide general-purpose micronic and submicronic particulate retention along with superior economy. The PES membrane offers excellent permeability at high flow rat...
E-PES-S Series polyethersulfone (PES) pleated filter cartridges provide general-purpose micronic and submicronic particulate retention along with superior economy. The PES membrane offers excellent permeability at high flow rates and low pressure drop. Being hydrophilic, cartridges allow for fast and easy wetting in aqueous fluids. The asymmetric membrane structure provides greater contaminant capacity versus traditional membranes. Component materials comply with US FDA and EU regulations for safe use with food and potable water.
Features
Durable PES and polypropylene components
Highly porous asymmetric membrane
Excellent chemical compatibility
Low extractables; low protein binding
Applications
Clarification of process water and other fluids
Deionized water systems
Recirculating fluid systems
Fine chemical filtration
Cleaning and disinfectant fluid filtration
Product Quality
Individual elements are identified by serial number.
Produced in a clean-room environment for product purity & cleanliness.
Manufactured within an ISO 9001:2015 certified quality management system.
Each filter element is inspected for compliance with requirements for manufactured cartridge integrity.
Meets USP Biological Reactivity Test requirements of the current USP <88> for Plastics Class VI-121°C.
Materials of Construction
Media:
Polyethersulfone
Support Layers:
Polypropylene
Cage/Core/End Caps:
Polypropylene
Adapter Reinforcement:
Polysulfone or Stainless Steel
Seal Options:
Silicone, NBR, EPDM, FKM, E-FKM
Dimensions
Diameter:
69mm (2.72")
Lengths:
10”, 20”, 30”, 40”
Operating Conditions
Operating Temperature:
80°C (176°F) max.
Operating dP (max.):
4 bar (58 psi) @ 20°C (68°F),2 bar (29 psi) @ 80°C (176°F)
Change-Out dP:
2.6 bar (38 psi) @ 20°C (68°F)
Sterilization Recommendations
Autoclave
125°C (257°F), 30 minutes, 30 cycles
Steam-in-Place (SIP):
125°C (257°F), 30 minutes, 30 cycles
Extractables, typical
Per 10” element:
﹤25mg non-dissolved solids
Clean Pressure Drop
Effluent Quality
Non-fiber releasing
Non-pyrogenic per USP Bacterial Endotoxin Requirements (>0.25EU/mL)
Effluent meets TOC, pH, and water conductivity requirements per USP Standards for Purified Water